ASNT NDT Level II — Study Guide
Credential: ASNT NDT Level II Issuing body: ASNT (American Society for Nondestructive Testing) Jurisdiction: USA — certification is employer-administered under SNT-TC-1A (the employer's written practice; certification is revoked on job change) or third-party under the ASNT 9712 scheme (ISO-9712 aligned) Level: Level II — the interpreter/operator: can set up and calibrate equipment, conduct tests, interpret and evaluate results, prepare written reports, and supervise Level I personnel Prerequisites: Documented training hours + work experience per method (example per the ASNT 9712 scheme: UT — 80 hours training, 1,600 hours experience with 840 in UT) Renewal: Every 5 years — by application or by examination Exam: General + Specific + Practical per method; minimum 70% on each, 80% composite
Level II is where NDT becomes a profession rather than a task. Level I follows a procedure; Level II understands the procedure well enough to know when it's lying.
1. Pathway — How the Certification Is Earned
- Meet training and experience. Each method (UT, RT, MT, PT, ET, VT, LT, AE, IRT) has required formal training hours and supervised work-experience hours. The hours scale with the method's complexity — UT and RT demand the most.
- Vision examination. Near-vision acuity and color-contrast discrimination (for PT/MT color indications) — documented annually in most written practices.
- Pass three exams per method. General (theory of the method — closed-book), Specific (the employer's procedures, codes, and acceptance criteria — often open-procedure), Practical (hands-on: calibrate, inspect specimens with known discontinuities, interpret, and write the report). 70% minimum each, 80% composite.
- Employer certification. Under SNT-TC-1A the employer certifies you via its written practice — change employers and you re-certify. Under ASNT 9712, certification is portable and ISO-9712 aligned.
- Renew every 5 years by application (documented continuing activity) or re-examination.
Critical context: SNT-TC-1A is a recommended practice, not a law — but it is contractually invoked by most US construction and fabrication codes, which gives it the force of law on a project. Know the difference when a contract cites it.
2. Knowledge Domains
Domain A — Method physics (General exam, all methods)
Ultrasonics (UT). Sound above human hearing (>20 kHz; weld inspection typically 2–5 MHz). Longitudinal waves (particle motion parallel to propagation — travel in solids and liquids) vs shear waves (perpendicular — solids only; the workhorse for weld inspection via angle-beam probes). Key relations: wavelength λ = v/f (v in m/s or in/µs, f in Hz); near field N = D²/4λ (D = transducer diameter) — inspections must be beyond the near field where the beam is chaotic; beam spread half-angle sin θ = 1.22λ/D — higher frequency and larger diameter give tighter beams. Snell's law governs mode conversion at the wedge: sin θ1/v1 = sin θ2/v2 — this is how a plastic wedge generates a 45°/60°/70° shear wave in steel. Acoustic impedance Z = ρv — reflection at an interface scales with impedance mismatch; couplant exists to exclude air (Z mismatch steel-to-air reflects ~100%).
Radiography (RT). X-ray (tube — bremsstrahlung + characteristic) vs gamma (isotope — Ir-192, Co-60, Se-75; fixed energies, no power needed). Attenuation: I = I0 e^(−μx) — thicker/denser material attenuates more, casting the shadow image. Geometric unsharpness Ug = (source size × OFD)/SOD — smaller source and closer film sharpen the image. IQI (penetrameter) — the image-quality indicator whose visible wire/hole proves the required sensitivity (typically 2-2T: see the 2T hole in the wire/hole whose thickness is 2% of the specimen). Film density (1.5–4.0 typical range) and the characteristic curve; scatter control (lead screens, collimation, backscatter "B" marker).
Magnetic particle (MT). Ferromagnetic materials only. A magnetic field is induced (yoke, prods, coil, head-shot); surface/near-surface discontinuities distort the field, creating flux leakage that attracts particles. Field direction must be perpendicular to the expected discontinuity — hence two perpendicular magnetizations for full coverage. AC (surface, mobile particles) vs HWDC (deeper penetration); prod spacing and current rules (typically 90–110 A per inch of prod spacing for HWDC, 4–6 in. spacing); particle types (dry visible, wet fluorescent — fluorescent is more sensitive).
Liquid penetrant (PT). Capillary action draws penetrant into surface-breaking discontinuities; developer draws it back out to form the indication. Steps: clean → apply penetrant → dwell (temperature- and material-dependent) → remove excess (water-washable, post-emulsifiable, or solvent-removable — removal method must not wash the defect) → apply developer → inspect under appropriate light. Visible dye (red on white developer) vs fluorescent (UV-A, darkened booth). PT finds surface-breaking defects only — and only on nonporous materials.
Eddy current (ET). AC coil induces eddy currents in conductive material; discontinuities perturb impedance, displayed as impedance-plane traces. Skin depth δ = √(ρ/πfμ) — higher frequency = shallower penetration (surface cracks); lower frequency = deeper (subsurface, tubing). Fill factor (tube inspection), lift-off (probe-to-surface distance — the dominant noise source), edge effects. Phase analysis separates defect signals from lift-off and permeability noise.
Visual (VT). Direct and remote (borescopes, cameras). Lighting, magnification, and — the Level II skill — knowing what to look for (the CWI-adjacent discontinuity vocabulary: cracks, undercut, overlap, porosity, misalignment).
Domain B — Calibration and technique (Practical exam core)
UT calibration. Distance calibration (IIW/V1 or V2 block — set the timebase so screen divisions equal known distances), sensitivity/TCG (time-corrected gain) or DAC (distance-amplitude correction) curves (equalize response across the inspection range — a reflector at 6 in. must read the same as at 2 in.), wedge delay and refracted-angle verification, resolution checks. The exam tests whether you calibrate before inspecting and whether you verify after (calibration checks bracket the work — drift invalidates results).
RT technique. Technique selection: source, film/detector, IQI placement (source side vs film side — and the "F" marker when film-side), exposure calculation from exposure charts, density verification. Film interpretation: distinguish porosity (round), slag (irregular), lack of fusion (linear, straight-edged), cracks (jagged linear), tungsten (bright white spots), undercut and burn-through signatures.
MT/PT technique. Bath concentration checks (settling test for wet fluorescent MT), UV-A intensity verification (≥1,000 µW/cm² at the surface), ambient light limits in the booth (<2 foot-candles for fluorescent), system performance checks (cracked chrome panel or known-defect specimens).
Domain C — Interpretation, evaluation, and codes (Specific + Practical)
Indication vs discontinuity vs defect. An indication is a response; a discontinuity is a real physical interruption; a defect is a discontinuity that exceeds the acceptance standard. Level II judgment lives in the second and third steps — and in knowing that relevant, nonrelevant, and false indications must be sorted before any evaluation (a magnetic particle buildup at a geometry change is nonrelevant; a scratch holding penetrant is false).
Acceptance criteria. From the construction code: ASME Section V (NDE methods) + Section VIII or B31.x (acceptance), AWS D1.1 Tables 6.1/8.1 (welds), API 1104 (pipelines). The Specific exam is open-procedure precisely because nobody memorizes all criteria — you must apply them: measure the indication, compare to the clause, disposition accept/reject/repair.
Reporting. The Level II report: equipment and calibration data, technique parameters, results sketch-mapped to the part, disposition, and traceability (procedure revision, personnel certification). The report is the legal record — in litigation, the inspection happened only if the report says so.
Domain D — Safety and the written practice
Radiation safety (RT). Time, distance, shielding; dosimetry (TLD/OSL badges, pocket dosimeters); boundary surveys (2 mR/hr controlled-area boundary per NRC/Agreement State rules); source handling and emergency procedures (crank-out source disconnect = the nightmare scenario — know the emergency response: evacuate, secure the boundary, notify the RSO). The General exam tests ALARA as a principle, not just a slogan.
The employer's written practice. Required by SNT-TC-1A: defines the levels, training/experience/exam requirements per method, vision requirements, and recertification rules for that employer. Level II personnel must know their own written practice — Specific exams are built from it.
3. Key Equations (with units and assumptions)
- Wavelength: λ = v/f. Steel shear wave: v ≈ 3,230 m/s (0.127 in/µs). At 2.25 MHz: λ ≈ 1.44 mm. Assumption: isotropic homogeneous material.
- Near field: N = D²/4λ. A 0.5-in. diameter, 2.25 MHz shear probe in steel: N ≈ 1.1 in. — inspect beyond this distance.
- Snell's law: sin θ_incident/v1 = sin θ_refracted/v1 = sin θ_shear/v_shear. Wedge (v ≈ 2,730 m/s) to steel shear (3,230 m/s): incident ~36.6° gives 45° shear. Assumption: planar interface.
- Attenuation (RT): I = I0 e^(−μx). μ in cm⁻¹, x in cm. Explains exposure charts — doubling thickness needs exponentially more exposure.
- Geometric unsharpness: Ug = (S × OFD)/SOD. Keep Ug below code limits (often ≤ 0.020 in. for the required sensitivity).
- Skin depth (ET): δ = √(ρ/πfμ). Copper at 1 kHz: δ ≈ 2 mm. Assumption: nonmagnetic (μ = μ0); ferromagnetic materials need saturation.
- MT prod current: ~90–110 A per inch of prod spacing (HWDC). Assumption: 4–6 in. spacing on steel under ~3/4 in. thick — verify against the procedure.
4. Worked Examples
Example 1 — UT beam check. A 2.25 MHz, 0.5-in. diameter shear-wave probe inspects a 1-in.-thick weld. Is the inspection in the near field? Step-by-step: v_shear (steel) ≈ 0.127 in/µs; f = 2.25 MHz → λ = 0.127/2.25 = 0.0564 in. N = D²/4λ = 0.25/(4 × 0.0564) = 1.11 in. The sound path in the weld (skip distances) typically exceeds this after the first leg — but the first inch of path is near-field: be cautious interpreting near-surface indications on short paths, and note it in the technique. Lesson: the exam tests whether you check, not whether you memorize N.
Example 2 — RT exposure change. A technique gives density 2.5 at 100 Ci-min exposure on 0.75-in. steel. What exposure for 1.0-in. steel at the same density? Step-by-step: Attenuation is exponential — use the exposure chart or the rule that each additional half-value layer doubles exposure. Steel half-value layer for Ir-192 ≈ 0.5 in. Additional 0.25 in. ≈ half a half-value layer → exposure × ~1.4 ≈ 140 Ci-min. Lesson: RT exposure scales exponentially with thickness — linear guessing underexposes. (Exact value from the chart; the method is what's tested.)
Example 3 — MT field direction. A longitudinal weld seam must be inspected for transverse cracks. How do you magnetize? Step-by-step: Field must cross the expected discontinuity — transverse cracks run across the seam, so the field must run along the seam: use a coil around the part or prods placed across... careful: prods create field between the prods, so place prods on either side along the seam axis to drive current across it, field lines running lengthwise. Then rotate 90° for longitudinal cracks. Lesson: "two perpendicular directions" is the procedure requirement because one direction is blind to parallel discontinuities.
Example 4 — PT dwell on a cold part. A procedure specifies 10-minute dwell at 60–125°F. The part is at 45°F in an unheated shop. Step-by-step: Stop. Below the qualified temperature range, penetrant viscosity rises and capillary action slows — dwell time is invalid and indications may not develop. Warm the part into range or qualify a new dwell. Lesson: the Specific exam tests procedure limits, not just procedure steps.
Example 5 — Indication evaluation. UT finds a reflector at mid-wall in a groove weld, 6 dB above the DAC curve, 1.5 in. long. D1.1 statically loaded, weld is 1-in. thick. Step-by-step: Amplitude alone doesn't reject — D1.1 UT acceptance (Annex Q / Table 6.3 logic) uses indication rating = amplitude − attenuation − length factors vs. the D-level thresholds. A +6 dB over DAC with 1.5-in. length on 1-in. material computes to a rating well into reject territory (Class D limits for static are around +5 to +11 dB depending on thickness/length). Lesson: UT acceptance is a calculation, not a feeling — run the rating.
5. Standards/Regulations Cross-Reference
- SNT-TC-1A: the recommended practice defining Levels I/II/III, training/experience/exam minima, and the employer's written practice. The organizational document behind the credential.
- ASNT 9712 / ISO 9712: the third-party, ISO-aligned certification scheme — portable across employers; 5-year renewal by application, 10-year re-examination.
- ASME BPVC Section V: NDE methods and requirements; Section VIII Div. 1/2, B31.1/B31.3, B31.8: acceptance criteria by construction code.
- AWS D1.1 Clause 6 + Annex Q: weld inspection and UT acceptance tables.
- API 1104: pipeline weld inspection criteria.
- ASTM E-series: E164 (UT welds), E94/E1742 (RT film), E709 (MT), E165 (PT), E1004 (ET) — the test-method standards behind the procedures.
- 10 CFR 34 / state radiography rules: RT licensing, boundary, and dosimetry requirements — the law behind the safety domain.
6. Pitfalls & Trap Patterns
- The 70/80 rule. 70% minimum each exam, 80% composite. A 100% Practical doesn't save a 68% General.
- Indication ≠ defect. Questions describe an MT buildup at a keyway and ask for disposition — it's nonrelevant until proven otherwise. Evaluate, don't just report.
- Field direction in MT. Every MT scenario question secretly asks "is the field perpendicular to the crack?" Get this reflex automatic.
- Calibration bracketing. Calibrate before, verify after. A procedure violation question often hides here.
- SNT-TC-1A is employer-based. "I was Level II at my last job, so I'm Level II here" — wrong. New employer, new certification (unless ASNT 9712).
- RT safety numbers. Boundary dose rates, dosimetry, and emergency response are free points if memorized — and the exam always asks.
- UT: amplitude is not size. A high-amplitude reflector can be a small favorably-oriented defect; a low-amplitude one can be a large rough crack. Sizing needs technique (6 dB drop, etc.), not just gain.
Exam strategy: General = physics — derive from λ=v/f, Snell, attenuation, skin depth rather than memorizing factoids. Specific = procedure application — read the actual procedure clause, including notes and exceptions. Practical = do the work in order (calibrate → inspect → interpret → report) and document everything; examiners fail sloppy documentation faster than missed calls.
7. Practice Problems
-
A 5 MHz longitudinal probe (v = 5,900 m/s in steel) inspects a 25-mm plate. Compute λ and the near-field length for a 12-mm diameter crystal. Answer: λ = 5,900/5,000,000 = 1.18 mm. N = 144/(4 × 1.18) = 30.5 mm — longer than the plate is thick; near-field effects dominate the first backwall. Use a smaller crystal or lower frequency, or account for it.
-
Why must MT inspection use two perpendicular field directions? Answer: Flux leakage requires the field to cross the discontinuity. A field parallel to a crack produces no leakage — that crack orientation is invisible. Two directions cover all orientations.
-
An RT film shows round dark spots scattered in a weld. MT of the same weld shows nothing. Interpret. Answer: Internal porosity (volumetric, round) — RT sees it, MT can't (subsurface, and porosity's weak leakage field). Consistent: volumetric defects are RT/UT territory.
-
A PT procedure's dwell is 10 min at 60–125°F. The inspector dwells 20 min at 55°F "to be safe." Identify the errors. Answer: Temperature below the qualified range invalidates the dwell (viscosity/capillary effects); extended dwell doesn't compensate for out-of-range temperature. Follow the procedure or requalify.
-
ET at 100 kHz vs 1 kHz on copper tubing: which finds surface cracks, which finds deeper wall loss? Answer: 100 kHz (shallow skin depth) for surface cracks; 1 kHz (deeper penetration) for wall loss — but with lower surface sensitivity. Frequency selection is depth selection.
-
Define the difference between a nonrelevant and a false indication, with one example each. Answer: Nonrelevant: a real magnetic/geometric response not from a defect (MT buildup at a keyway). False: no discontinuity at all — contamination holding penetrant (a scratch or lint).
-
Under SNT-TC-1A, a newly hired Level II from another company wants to inspect on day one. What must happen first? Answer: The new employer must certify them under its own written practice — review of records, possibly re-examination (General/Specific/Practical per the practice). Prior certification doesn't transfer.
Original ETS reference writing, verified against public sources on 2026-09-30. Thin sourcing is flagged inline. Not legal advice — confirm current editions with the issuing body.