Certification · license to practice
Professional Engineer (PE) — Fire Protection
NCEES (exam) / US state engineering licensing boards (license) · US (state-level licensure) · professional
Requires: Accredited engineering degree, Fundamentals of Engineering (FE) exam, ~4 years progressive experience, pass PE Fire Protection exam (85 questions, 9.5-hour appointment, administered one day per year; next test date April 13, 2027)
Renewal: State-board renewal (estimated: typically biennial with professional development hours; varies by state)
Certification · flagship
Certified Fire Protection Specialist (CFPS)
NFPA (National Fire Protection Association) Certification Department · International (US-based) · professional
Requires: ONE of: bachelor's/master's in fire-protection-related or engineering discipline + 2 years verifiable fire-loss-prevention experience; associate's in related field (or bachelor's in unrelated field) + 4 years; high school diploma + 6 years. Open-book exam: 100
Renewal: 3-year validity (estimated: renewal via NFPA certification management system; older brochures cite ~USD 125/yr + 50 rece
Certification
Certified Water-Based Systems Professional (CWBSP)
NFPA Certification Department · International (US-based) · advanced
Requires: Minimum 5 years full-time verifiable work experience in design of water-based fire protection systems. Open-book CBT: 100 questions, 3 hours, based on NFPA 13, 13D, 13R, 14, 20, 22
Renewal: estimated: NFPA 3-year certification cycle (not confirmed in this pass)
Certification
Water-Based Fire Protection System Inspection, Testing, and Maintenance (WBITM) Certification
NFPA Certification Department · International (US-based) · advanced
Requires: Minimum 5 years full-time verifiable ITM experience with water-based systems plus supervisor/employer attestation of knowledge, skills, abilities
Renewal: estimated: NFPA 3-year certification cycle (not confirmed in this pass)
Certification · flagship
NICET Fire Alarm Systems Certification (Levels I–IV)
NICET (National Institute for Certification in Engineering Technologies) · US (widely referenced by AHJs; NFPA 72 §10.5.2 requires certification by an approved third-party organization where states lack licensing) · Level I (6 months exp) → Level II (2 yrs) → Level III (5 yrs, design + project management) → Level IV (10 yrs + major-project writeup, 5-hour exam)
Requires: Progressive industry experience per level plus exams and performance measures; Level IV requires senior engineering-technician responsibility and a major project of substantial complexity
Renewal: estimated: NICET 3-year recertification cycle with continuing professional development (not confirmed in this pass)
Certification
NICET Water-Based Systems Layout Certification (Levels I–IV)
NICET · US · Level I–IV (sprinkler/standpipe layout)
Requires: Progressive experience in water-based fire protection layout; several states accept NICET Level III/IV sprinkler layout as qualification evidence
Renewal: estimated: NICET 3-year recertification cycle (not confirmed in this pass)
Certification
NICET Special Hazards Systems Certification (Levels I–IV)
NICET · US · Level I–IV (special hazard suppression: clean agent, CO2, foam, dry chemical)
Requires: Progressive industry experience per level plus exams; engineering-technician track parallel to fire alarm and water-based programs
Renewal: estimated: NICET 3-year recertification cycle (not confirmed in this pass)
Certification · license to practice
Minnesota Fire Protection Contractor License (managing employee + journeyman sprinkler fitter)
Minnesota State Fire Marshal / MN Department of Public Safety · US — Minnesota (example; many states have analogous mandatory sprinkler-contractor licensing) · contractor / trades license
Requires: Managing employee: 10,000 hours fire-protection work OR NICET Level III/IV sprinkler layout OR PE with fire protection competency; journeyman sprinkler fitter: 8,000 hours or completed apprenticeship; exam ≥70%
Renewal: Annual: licenses valid July 1–June 30, renewal due May 31; 10 hours continuing education per cycle
Certification
SFPE Individual Credential — does not exist
SFPE (Society of Fire Protection Engineers) · International · n/a
Requires: n/a
Renewal: n/a
Standard
NFPA 13 — Standard for the Installation of Sprinkler Systems
NFPA · US (adopted by reference in most US fire codes); NFPA 13D/13R cover one/two-family and low-rise residential · design/installation standard
Requires: n/a
Renewal: n/a
Standard
NFPA 72 — National Fire Alarm and Signaling Code
NFPA · US (adopted by reference; §10.5.2 personnel-qualification rule gives NICET de-facto weight) · design/installation/ITM standard
Requires: n/a
Renewal: n/a
Standard
NFPA 101 — Life Safety Code
NFPA · US (adopted statewide in 40+ states either directly or by reference; CMS mandates 2012 edition for Medicare/Medicaid healthcare facilities) · model code
Requires: n/a
Renewal: n/a
Standard
NFPA 70 — National Electrical Code (NEC)
NFPA · US (reported adopted in all 50 states) · installation standard
Requires: n/a
Renewal: n/a
Standard
NFPA 25 — Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems
NFPA · US (adopted by reference in fire codes; underpins WBITM certification and contractor ITM contracts) · ITM standard
Requires: n/a
Renewal: n/a
Standard
NFPA 5000 — Building Construction and Safety Code
NFPA · US (alternative comprehensive building code to IBC; low adoption) · model building code
Requires: n/a
Renewal: n/a
Standard
ICC International Fire Code (IFC)
International Code Council (ICC) · US (model code; enforceable only as adopted/amended by state or local jurisdiction) · model fire code
Requires: n/a
Renewal: n/a
Standard
ICC International Building Code (IBC) — fire provisions
International Code Council (ICC) · US (model building code adopted at state/local level) · model building code
Requires: n/a
Renewal: n/a
Standard
EN 12845 — Fixed firefighting systems: Automatic sprinkler systems — Design, installation and maintenance
CEN (European Committee for Standardization); national adoptions e.g. BS EN 12845 · EU/EEA + UK (via national adoptions) · design/installation/maintenance standard
Requires: n/a
Renewal: n/a
Regulation
State Fire Marshal / Authority Having Jurisdiction (AHJ) — plan review, permits, inspections, approvals
State fire marshal offices and local fire code officials (fire departments) · US (state and local) · enforcement authority
Requires: n/a
Renewal: n/a
Regulation
OSHA 29 CFR 1910 Subpart L — Fire Protection (workplace fire safety)
US Occupational Safety and Health Administration (federal) · US federal (employers) · federal regulation
Requires: n/a
Renewal: n/a
Regulation
EU Construction Products Regulation (EU) No 305/2011 (CPR) — fire-rated construction products
European Parliament / Council (EU) · EU/EEA · EU regulation
Requires: n/a
Renewal: n/a
No records match.